Description: 3-Channel 12 Lead Features:7 inch graphic LCD display,touch screen and function key control at the same time, more convenient and shortcut.Three?channel ECG machine with interpretationAuto-regulation of baseline drift can effectively inhibit baseline drift, optimizing the printing position to achieve high-quality ECG.With?automatically measuring and analyzing function for ECG parameters to reduces the doctor’s burden and improves work efficiency.With a high resolution thermal printer to print out ECG trace,describing the trace?clear and accurate,annotation as well as related parameters for diagnostic reference.12-lead ECG simultaneous acquisition.Adapt 110-240V, 50/60Hz AC power supply.Specifications:Leadstandard 12 leadslead acquisitionsynchronously?12 leadsInput circuitFloating; Protection circuit against Defibrillator effectInput Impedance≥50MΩInput circuit current≤0.0.05μARecord modeAutomatic: 3CH×4+1R, 3CH×4, 3CHx2+2CHx3,3CHx2+2CHx3+1R,6CHX2;Manual: 3CH, 2CH, 3CH+1R, 2CH+1R;Rhythm: Any lead selectable.FilterEMG Filter: 25 Hz / 30 Hz / 40Hz/75 Hz / 100 Hz / 150HzDFT Filter: 0.05 Hz/ 0.15 HzAC Filter: 50 Hz / 60HzCMRR>100dBPatient current leakage<10μAInput Circuit Current<0.05μAFrequency Response0.05Hz~150Hz (-3dB)Sensitivity?2.5mm/mV, 5 mm/mV, 10 mm/mV, 20 mm/mVAnti-baseline DriftAutomaticTime constant≥3.2sNoise level<15μVp-pPaper speed12.5 mm/s, 25 mm/s, 50 mm/sRecording modeThermal printing systemPaper specification80mmx20m?paper?rollLCD display7”?graphic LCDSafety classificationIEC60601-1 class I, type CFPower supplyAC:?100~240V, 50/60Hz, 30VA~100VA?DC: 14.8V/2200mAh, built-in lithium batteryFuseAC220V±10% ?2*Φ5×20mm,T2A/250V ?AC time lag ??AC110V±10% ?2*Φ5×20mm,T4A/250V ?AC time lag Package List:ECG Machine×1ECG Lead Wire×1Limp Clip×4Chest Suction Ball×6Thermal Printing Paper×1Fuse×1Power Cable×16-Channel 12 LeadDescription: Features:7 inch graphic LCD display,touch screen and function key control at the same time, more convenient and shortcut.Six?channel ECG machine with interpretationAuto-regulation of baseline drift can effectively inhibit baseline drift, optimizing the printing position to achieve high-quality ECG.With?automatically measuring and analyzing function for ECG parameters to reduces the doctor’s burden and improves work efficiency.With a high resolution thermal printer to print out ECG trace,describing the trace?clear and accurate,annotation as well as related parameters for diagnostic reference.12-lead ECG simultaneous acquisition.Adapt 110-240V, 50/60Hz AC power supply.Specifications:Leadstandard 12 leadslead acquisitionsynchronously?12 leadsInput circuitFloating; Protection circuit against Defibrillator effectInput Impedance≥50MΩInput circuit current≤0.0.05μARecord modeAutomatic: 3CH×4+1R, 3CH×4, 3CHx2+2CHx3,3CHx2+2CHx3+1R,6CHX2;Manual: 3CH, 2CH, 3CH+1R, 2CH+1R;Rhythm: Any lead selectable.FilterEMG Filter: 25 Hz / 30 Hz / 40Hz/75 Hz / 100 Hz / 150HzDFT Filter: 0.05 Hz/ 0.15 HzAC Filter: 50 Hz / 60HzCMRR>100dBPatient current leakage<10μAInput Circuit Current<0.05μAFrequency Response0.05Hz~150Hz (-3dB)Sensitivity?2.5mm/mV, 5 mm/mV, 10 mm/mV, 20 mm/mVAnti-baseline DriftAutomaticTime constant≥3.2sNoise level<15μVp-pPaper speed12.5 mm/s, 25 mm/s, 50 mm/sRecording modeThermal printing systemPaper specification110mmx20m?paper?rollLCD display7”?graphic LCDSafety classificationIEC60601-1 class I, type CFPower supplyAC:?100~240V, 50/60Hz, 30VA~100VA?DC: 14.8V/2200mAh, built-in lithium batteryFuseAC220V±10% ?2*Φ5×20mm,T2A/250V ?AC time lag ??AC110V±10% ?2*Φ5×20mm,T4A/250V ?AC time lag Package List:ECG Machine×1ECG Lead Wire×1Limp Clip×4Chest Suction Ball×6Thermal Printing Paper×1Fuse×1Power Cable×1 This product bears CE mark and the notified body is 0482 EC certificate No.: 6730GB410160520 Report No.: 6730FS06F FDA Disclaimer: The following FDA Disclaimer is required for all eBay listing in Healthcare category and is included for REFERENCE: ARTG NO: 278908 ARTG Number: 278908 Statement: The sale of this item may be subject to regulation by the U.S. Food and Drug Administration and state and local regulatory agencies. If so, do not bid on this item unless you are an authorized purchaser. If the item is subject to FDA regulation, I will verify your status as an authorized purchaser of this item before shipping of the item.?(The seller name: Helen Zhang,City:Beijing State: Beijing Country: China Telephone number: 86-18730611603) This item has been cleaned and treated according to the manufacturer's instructions.? The Fingertip Pulse-Oximeter is registered on the Australian Register of Therapeutic Goods (ARTG) with the code 136606, and certified by FDA of United States (Premarket Submission Number (510K): K073454 Listing Number: D045684, K082641 Listing Number: D064765, K090671 Listing Number: D078664); and CE Approved, TUV of Europe (Cert.No. : G1 10 02 50972 013).
Price: 362.43 USD
Location: Los Angeles, California
End Time: 2024-11-23T04:15:00.000Z
Shipping Cost: 0 USD
Product Images
Item Specifics
Restocking Fee: No
Return shipping will be paid by: Buyer
All returns accepted: Returns Accepted
Item must be returned within: 30 Days
Refund will be given as: Money Back
Custom Bundle: No
UPC: 190891270986
MPN: Does Not Apply
Bundle Listing: Yes
Modified Item: No
Intended Use/Discipline: Cosmetology
Brand: Carejoy
Number of Leads: 12
Model: Portable 3-Channel Electrocardiograph
warranty: 2 years
ECG & EKG Machine Type: Electrocardiograph
Features: Printer
Country/Region of Manufacture: United States
Application: Resting
Available Variations
Color: 6-Channel 12 lead
Price: 362.43 USD
Available Quantity: 1
Quantity Sold: 1
Color: 3-Channel 12 lead
Price: 393.54 USD
Available Quantity: 1
Quantity Sold: 0